What tools do I need to cut flexible metallic conduit?
Jul 26, 2017 · I need to cut 3/8" flexible metallic conduit and am looking for suggestions on how to cut it (i.e. Conduit Tubing cutter, hacksaw). How do you smooth the edges that were just cut?
How can I cut a metal pipe while preserving the wires inside?
Oct 5, 2019 · A pipe cutter will leave an inwards facing sharp edge at a reduced diameter. If the conduit is full wires will be damaged. With wires there there's no easy way to remove this "anti …
Flex metallic conduit touching drywall - Home Improvement Stack …
Apr 14, 2022 · Is it acceptable to insert metallic flex conduit into a non-metallic box, assuming the conduit is bonded on the other end to a grounded metallic box? Is it acceptable to use a bare …
How many 12-2 cables can I put in a short run of conduit?
Jan 17, 2017 · Would this be acceptable to pull two 12-2 cable per 3/4" conduit at least for the first 2 outlets or do I need to put in a junction box along the way and then just run a 1/2" down to …
Wiring for water heater and dryer - Home Improvement Stack …
May 25, 2023 · Complete, correctly connected non-flex metallic conduit is a ground conductor - so you don't need a grounding wire in it (that's why 5, not 6 wires - two hots for the charger, plus …
electrical - How should transitions from inside to outside be …
Jan 21, 2021 · So maybe it would make more sense to transition from the wall cavity into flexible water tight conduit and then into the disconnect. Or maybe the solution is to run the entire …
Can flexible conduit be used inside PVC conduit?
Oct 5, 2023 · Can 3/4" Liquid Tight Non Metallic Flexible Conduit be run inside a PVC Sch 40 and buried 18" below ground for extra water tight for electrical wires (3 of 6awg and 1 …
code requirements for conduit attached to a bridge
Nov 8, 2023 · Schedule 40 1 1/2" conduit with hangers every 4 feet? The bridge length is 12 feet. Does the code require a transition to flex conduit on both sides of the bridge? Does liquid tight …
Should I use non-metallic conduit instead of PVC?
Jun 16, 2021 · I would put EMT in over NM liquid tight any day. Non metallic liquid tight is easily damaged or cut compared to rigid PVC or EMT. Both rigid pvc and EMT are easier to pull than …
electrical - How to connect schedule 40 PVC conduit to an …